Model 50C - Applications

Overview Operation Applications Specifications


CHIP PACKAGE

Planar parts such as electronic packages can be inspected with the Model 50C in the vertical tilt position (see Figure 1, Tilt Positions, Model 50C - Operation ).   In this orientation, a shorter focal length lens can be used in the Optimet sensor.  In the figure below, a 25 mm lens was used instead of the usual 75 mm lens.  Although the depth of field is only a few millimeters, a planar part mounted horizontally on the turntable fits within this narrow depth of field.

The part is a portion of an electronic package that connects a silicon chip to a PC board without stressing the chip's connections by differential expansion when the chip gets hot. A critical part of the package is an array of small bumps called "nubbins" that keep the chip the proper distance from the PC board.  Shown below is a topology map of a 3 x 3 nubbin array.  Note that the vertical scale has been exaggerated to emphasize the nubbin shape; a nubbin is only 0.1 mm (4 thou) high, but is .625 mm (25 thou) between centers.

NubbinsWeb.jpg (41000 bytes)
             Figure 1.  Nubbin Array

The inspection task was to have the same machine find the height for each nubbin in a large 8 x 8 array, but also have "detail" capability to check the shape of a single nubbin.  Below is a topology map of a single nubbin, again with the vertical scale exaggerated.  Points on the map are accurate to a few microns at the higher resolution of the 25 mm lens.

SingleNubbinWeb.jpg (41000 bytes)
             Figure 2.  Single Nubbin


COPLANARITY

Another planar part is the chip carrier package shown in the figure below. The carrier has 360 leads around its periphery deployed in 120 "lead sets", each having 3 rows of leads.  The figure shows one of four sides of the package having 30 lead sets.  The inspection task is to check the leads for coplanarity: do the tips of the leads lie in the same plane.

PackageSideWeb.jpg (53000 bytes)
             Figure 3.  One side of Chip Package

Two lead sets that were sliced out of the figure above are shown magnified in the image below.  The Model 50C is in the vertical tilt position to measure the lead sets from above.  The thin red lines below show how each lead of the set bends 90 degrees, penetrates the package rim and ends in the interior of the package.  The lead tips to be inspected are circled in blue.

LeadDataCloudWeb.jpg (74000 bytes)
             Figure 4.  Datacloud of Two Lead Sets

The tips of several lead sets are shown in the topology map below.  As before each lead set consists of 3 adjacent leads.  The color coding on the vertical scale covers a range of just 0.1 mm (4 thou).  Although each tip is just 0.2 mm (8 thou) wide by 0.3 mm (12 thou) long, the topology of each one can be clearly seen.

CoplanarityWeb.jpg (46000 bytes)
             Figure 5.  Lead Coplanarity


TUBULAR PARTS

When the Model 50C is changed to its horizontal tilt position (see Model 50C - Operation), it can accurately measure tubular parts.  The Allen head bit measuring 6.25 mm (.25") across flats was fixtured vertically and rotated to scan each side of the part.  Notice how much more crisp the confocal optics datacloud is than one using laser triangulation on a part of approximately the same length (see Figure 2, Data Cloud, Example ).   Crisper dataclouds mean better dimensional resolution.

AllenBitWeb.jpg (67000 bytes)
             Figure 6.  Allen Head Bit